Add to Cart
Where Compressor Water Separator being Use?
The gas-water separator is mainly used to separate gas and liquid in industrial liquid-containing systems to improve the drying degree of steam and reduce the phenomenon of steam with water. Commonly used compressed water separator include tubular separators, louvered separators, High Efficiency cyclone separators and so on. YUKA air water separator with 99.73% separation performance, which eliminate liquid/mositure and water from the compressed air system well.
Compressed Gas Separator Feature& Advantage
> 99.73% efficiency of condensate removal from compressed air system
> Zero Pressure Drop, saving energy and money for ownership
> Air Compressor Separator Inside & Outside resistace corrosion Treatment, prevent second pollution
TECHNICAL SPECIFICATION
Model | Pipe size | Flow rates | Dimension(mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C (clearance for housing) | ||
FWS010 | RC1/2" | 40.0 | 2.4 | 84.5 | 96 | 79 | 233 | 29 | 198 | 118 |
FWS020 | RC3/4" | 60.0 | 3.6 | 127.1 | 96 | 79 | 233 | 29 | 198 | 118 |
FWS050 | RC1" | 75.0 | 4.5 | 158.9 | 96 | 79 | 268 | 29 | 233 | 153 |
FWS060 | RC1" | 125.0 | 7.5 | 264.8 | 138 | 111 | 339 | 37 | 296 | 208 |
FWS070 | RC1-1/2" | 166.7 | 10.0 | 353.1 | 138 | 111 | 339 | 37 | 296 | 208 |
FWS100 | RC2" | 300.1 | 18.0 | 635.6 | 174 | 142 | 669 | 58 | 607 | 469 |
FWS110 | RC2-1/2" | 416.8 | 25.0 | 882.8 | 174 | 142 | 669 | 58 | 607 | 469 |
FWS131 | RC2-1/2" | 700.0 | 42.0 | 1483.1 | 220 | 184 | 726 | 74 | 649 | 514 |
FWS140 | RC3" | 833.5 | 50.0 | 1765.6 | 220 | 184 | 726 | 74 | 649 | 514 |
FWS140F | DN80/DN100 | 833.5 | 50.0 | 1765.6 | 300 | 184 | 746/761 | 74 | 649 | 514 |
FWS150 | RC4" | 1000.2 | 60.0 | 2118.7 | 220 | 184 | 726 | 74 | 649 | 514 |
FWS150F | DN100/DN125 | 1000.2 | 60.0 | 2118.7 | 300 | 184 | 761/776 | 74 | 649 | 514 |
FWS170 | RC4" | 1166.7 | 70.0 | 2464.0 | 220 | 184 | 983 | 74 | 906 | 764 |
FWS170F | DN100/DN125 | 1166.7 | 70.0 | 2464.0 | 300 | 184 | 1018/1033 | 74 | 906 | 764 |
Technical requirements | Maximum operating pressure: 10 barg Operating temperature:1.5°C~ 80°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |